YJ-PX1.8B
Compact portable X-ray system. The supplied product document is the authoritative source for its parameters and configuration options.
View model →The YJ-PX5.6 portable X-ray system combines a 5.6 kW high-frequency generator, a lightweight control head and optional simple, standard or high-configuration mobile stands. Wired or wireless exposure modes support clinic, bedside and mobile imaging workflows.
The supplied materials show the same control head with multiple stand options. Confirm the final stand, detector workflow, exposure mode, electrical supply and accessory set for each project.

Compare generator output, head weight and stand configuration, then open a model page for the full specification. More portable models can be added to this directory as they are released.

Compact portable X-ray system. The supplied product document is the authoritative source for its parameters and configuration options.
View model →
5.6 kW portable X-ray with a 40-125 kV range, 0.6 / 1.8 mm focal spots and optional simple, standard or high-configuration mobile stands.
View model →
8 kW analog portable X-ray system for clinic, bedside and mobile radiography. Full parameters are listed in the supplied product document.
View model →
8 kW storage portable X-ray with a 40-125 kV range, 10-160 mA, wired or wireless exposure and a 0.6 / 1.8 mm focal spot.
View model →
Battery-powered ultra-compact X-ray series at 450 W / 900 W with a 40-90 kV range and 0.8 focal spot. The supplied document is authoritative.
View model →The head can be used with a simple stand, standard mobile stand or high-configuration stand with a larger movement range and workstation shelf.



The system focuses on portability, quick setup and simplified exposure control.
Compact generator and X-ray tube assembly for general radiography workflows.
Wired and wireless exposure modes are both supported.
A 10.4-inch control interface presents anatomical selection and exposure settings.
The control head measures 285 x 230 x 526 mm and weighs 18 kg.
The head is common across the supplied configurations; the support structure changes with the intended workflow and budget.

Large movement range, workstation shelf and castor base for flexible room or bedside positioning.

Balanced mobility and positioning for clinics, small hospitals and mobile service use.

Compact support structure for projects that prioritize low weight and basic positioning.

5.6 kW generator, high-frequency control and a collimator integrated into the compact head.

The supplied concept image shows a fitted transport case for the control head and accessories.

285 x 230 x 526 mm control-head dimensions from the supplied mechanical drawing.
Values are taken from the supplied 5.6 kW product data. Support-stand dimensions and accessories must be confirmed by configuration.
| Model | YJ-PX5.6 |
|---|---|
| Input voltage | AC 110 / 220 V |
| Power | 5.6 kW |
| kV range | 40-125 kV |
| mA range | 2-100 mA |
| mAs range | 0.1-320 mAs |
| Communication | RS232 |
| Exposure mode | Wired or wireless |
| Focal spots | 0.6 / 1.8 mm |
|---|---|
| Anode angle | 15 degrees |
| Collimator power | AC/DC 24 V, plus or minus 10% |
| Light source | LED, 5 W |
| Light delay | 30 plus or minus 2 seconds |
| Illumination | At least 160 lux |
| Intrinsic filtration | 1.2 mm Al at 75 kV |
| Control head size | 285 x 230 x 526 mm |
|---|---|
| Control head weight | 18 kg |
| Control interface | 10.4-inch touch screen as indicated in the supplied materials |
| Transport | Protective fitted case shown in the supplied configuration |
| High configuration | Large mobile stand with workstation shelf and extended positioning travel |
|---|---|
| Standard configuration | General-purpose mobile stand for clinic and hospital use |
| Simple configuration | Lightweight support base for compact projects |
| Head only | Portable head can be discussed as a standalone configuration |
| Detector workflow | Wired or wireless exposure mode; confirm detector pairing and software by project |
| Final selection | Stand, detector, battery, accessories, packing and market requirements must be confirmed before quotation |
The supplied material describes multiple stand configurations with the same control head. Confirm the exact mechanical assembly, detector, battery, exposure control, packing and destination-market requirements.
The portable head and optional mobile stands can be positioned around the patient or workspace instead of moving the patient to a fixed room. The exact workflow depends on the detector and imaging software paired with the generator.
We will review the project and confirm the generator, support, detector, packing and market requirements before quotation.