5 kW high-frequency generator
High-frequency output with combined oil-cooled tube assembly for long image acquisition sessions.
The YJ-CA300 combines a 5 kW high-frequency generator, 9 x 9 inch amorphous-silicon flat panel detector and dual-monitor imaging workstation. It is designed for orthopedics, neurosurgery, pain management, vascular and emergency workflows.
The supplied catalog lists a 210 x 210 mm detector and a 1024 x 1024 image matrix. Confirm the final detector, monitor, generator and clinical configuration for each project.

The large opening and mobile base support fluoroscopy in operating rooms, intervention suites and emergency departments.



The supplied configuration focuses on image detail, live imaging speed and control flexibility in surgery.
High-frequency output with combined oil-cooled tube assembly for long image acquisition sessions.
Amorphous-silicon detector with CsI deposition, 210 x 210 mm active area and up to 30 fps.
27-inch LCD HD touch monitor shows live images and reference images simultaneously.
Hand switch, foot switch and remote control support exposure inside or outside the operating area.
These images show the detector, combined high-voltage generator, inverter module and real debugging setup.

210 x 210 mm active area, 16-bit conversion, 1024 x 1024 image matrix and up to 30 fps.

5 kW high-frequency generator with oil-cooled combined tube and high-voltage components.

Modular power electronics support compact system integration and service access.

The supplied image shows the assembled system during factory testing and imaging verification.

27-inch LCD HD touch monitor for live and reference images, with a separate mobile monitor cart.

Modular construction, error-code display, reset and service access on the mobile C-arm base.
Values are taken from the supplied C-arm catalog. Final detector, monitor and generator configuration must be confirmed for each order.
| Model | YJ-CA300 |
|---|---|
| Power output | 5 kW |
| Radiography current | 0.1-100 mA |
| Radiography voltage | 40-125 kV |
| mAs | 0.2-100 mAs |
| Continuous mA | 0.3-6.3 mA |
| Focal spot | 0.3 / 0.6 |
| Generator type | High-frequency generator |
| Detector type | Flat panel detector |
|---|---|
| Detector technology | Amorphous silicon with CsI deposition |
| Detector size | 9 x 9 in; 210 x 210 mm active area |
| A/D conversion | 16 bit |
| Spatial resolution | 2.5 lp/mm |
| Image matrix | 1024 x 1024 listed as pixel size in the supplied sheet |
| Maximum frame rate | 30 fps |
| Laser localizer | Included in the supplied feature description |
| Free opening | 820 mm |
|---|---|
| Monitor | 27-inch LCD HD touch monitor |
| Image display | Live video and reference images shown simultaneously |
| Generator module | Combined high-voltage generator |
| Power electronics | Modular inverter power module |
| Control | Microcomputer control with self-diagnostic function and automatic protection |
| Service | Modular design with error codes and reset button; dual CPU control |
| Exposure control | Hand switch, foot switch and remote control |
| Orthopedics | Orthopedic and trauma surgery guidance |
|---|---|
| Neurosurgery | Intraoperative fluoroscopy workflows |
| Pain management | Interventional procedure support |
| Other applications | Vascular, urology, radiotherapy, anesthesiology, radiology and emergency room |
| Connectivity | DICOM 3.0 and PACS connectivity |
| Data handling | Send, receive and print images through the imaging workstation |
The catalog describes a 9 x 9 inch detector and 1024 x 1024 image matrix. Confirm final monitor, detector, generator, software, table and accessory scope with the quotation.
The system is designed for intraoperative orthopedic and trauma procedures, neurosurgery, pain management and selected vascular, urology and emergency applications. The mobile C-arm and separate monitor cart can be positioned around the procedure room.
We will review the procedure room, imaging workflow, regulatory scope and accessories before confirming the quotation.